Dulcodes UV-Desinfektionsanlage

Operating

8

Operating

This section describes all operating options available to you when the S2Ca is in continuous
display mode (no P key symbol in the LCD display).

WARNING

• For all metering pumps for metering inflammable media applies: Starting up and

emptying only supervised by a competent person.

NOTE

• Open out the fold-out page following the title page fully! There you will find the overviews

“control elements and key functions” and “operating/settings diagram”.

• Look at the overview “continuous displays”. This page shows you which displays are

available in which operating mode, and which values are directly alterable in the
corresponding continuous displays.

8.1

Manual operation

Set stroke length

Stroke length is continually adjustable within a range of 0-100 %. The recommended stroke
length range, which will practically guarantee technical reproducibility, is 30-100 % (SEK type:
50-100 %).

NOTE

At low stroking rates (less than 1/3 maximum stroking rate) the controller switches to
digital stroking mode. This ensures adequate cooling of the motor at low stroking rates.

The following operating options are available via the different keys (see also figure on the next
page):

Stop/Start S2Ca

To stop S2Ca: press STOP/START key.
To start S2Ca: press STOP/START key.

Start batch

Press the P key briefly in “batch” operating mode.

Load factory settings

Press the P key for 15 s to load factory calibration settings!
Current settings will be deleted.

Change to settings mode

When you press the P key for 2 s in any continuous display the S2Ca will change to settings
mode (see section 7).
If CODE 1 is set, the code must be entered after pressing the P key.

Check adjustable values

Each time you press the i key you will see a different continuous display. The number of
continuous displays depends upon the identity code, the selected operating mode and the
connected accessories.

Change directly

alterable values

To change a value (see below) directly in the corresponding continuous display, press one of
the arrow keys until “set” appears in the LCD display. The delay has been programmed in to
prevent inadvertent changing of values.

If CODE 2 has been set, this code must be entered after pressing the arrow key.

Directly alterable values are as follows:

Stroke rate

In “manual”, “contact” and “batch” operating modes:
The stroke rate can be altered in the “stroke rate” display.

Feed rate

In “manual” operating mode
The feed rate can be altered in the “feed rate” display.

Factor

The factor is the number of strokes activated by an external pulse or a press of the P key (in
“batch” mode only).

In “Batch” operating mode:
You can alter the factor from the “remaining strokes” display.
The S2Ca returns to the original continuous display a few seconds after the factor has been
reset.

Display program version

Press the P key for 10 seconds to display the program version.
Example: “V1052” + “X1010”.
In the case of “LOAD3” release the key immediately!