The programmable function “auxiliary frequency” allows switching to a different stroke
frequency, which can be set in the AUX menu. It can be activated via the “external control”
terminal. When the auxiliary frequency is activated, “aux” appears in the LCD display.

This auxiliary frequency overrides the current stroke frequency set for the selected operating
mode.

7.5.3

Settings for the “flow” function (FLOW menu)

P

P

P

P

Continuous

display

w

o

l

f

Set

n

o

Set

Flow

8

0

0

Set

Flow

t

e

s

The flow menu only appears when a dosing monitor is connected to the “dosing monitor”
terminal. This dosing monitor registers each discharge stroke of the S2Ca at the discharge
connector and transmits it back to the S2Ca. If this response transmission is serially omitted
for a period set in the FLOW menu (due to failure or below-minimum dosing) the S2Ca stops.

7.6

Setting code (CODE menu)

The code menu is used to select whether you want to prevent access to parts of the settings
options.

P

P

P

Continuous

display

e

d

o

c

1

e

d

o

c

2

3

4

5

In the first menu option you can choose CODE 1 or CODE 2 (both use the same number).

Select CODE 1 to prevent access to the settings mode (

➀ in the overview “operating/

settings diagram”, fold-out page). In the next menu option, enter the number you wish to
use as the code.

Select CODE 2 to prevent access to the settings options for directly alterable values in the
continuous displays (

➁ in the overview “operating/settings diagram”, fold-out page). In the

next menu option, enter the number you wish to use as the code.

Select NONE to remove a pre-set security lock.

7.7

Cancel total stroke number or total litres (CLEAR window)

In the CLEAR window you can delete the stored total stroke number and simultaneously the
total litres (= set to “0”). You may then press the P key briefly to exit this window.

The values displayed are counted incrementally from the point of commissioning the pump, or
from the last delete action.

P

Continuous

display

r

a

e

l

c

L

N

Advertising
This manual is related to the following products: