Features of the S2Ca metering pumps

2

1

4

green/NC

white/NO

brown/C

pacing relay

fault indicating relay

yellow/NO

white/NO

green/NC

brown/C

1

4

3

2

2

3
1

4

Technical data, relay (control version)

Pump type S2Ca

Relay

Fault-indicating relay

Fault-indicating relay + pulse generator

Relay type

Fault-indicating relay

pulse generator

Fault-indicating relay

Voltage, max:

250 V 50/60 Hz

24 V DC

24 V 50/60 Hz

Current, max.

2 A (ohmic)

100 mA

100 mA

Hook up duration

100 ms

Behaviour

see Identcode

see Identcode

see Identcode

Service life

> 200 000 cycles*

> 50 x 10

6

(10 V 10 mA)

> 200 000 cycles

Relay type

Power relay

Voltage, max.

250 V (50/60 Hz)

Current, max.

16 A (ohmic)

Hook up duration

Behaviour

see Identcode

Service life

> 30 000 cycles*

* in the case of nominal load

The contacts are zero volt.

N/C fault indicating relay - the relay closes immediately after the power is switched on and opens
in the event of a fault.

N/O fault indicating relay, the relay closes in the event of a fault.

Use suitable interference suppression (e.g. RC glands) when connecting inductive loads.