Product description S2Ba/S2Ca

Material in contact with metered medium

Liquid end:

Parts of diaphragm failure monitor in contact with medium

Lens, seals

Intermediate disc Item 147,

Item 148, 156, 159

intermediate bush Item 150

PVDF

PTFE

PVDF

Stainless steel 1.4571

PTFE

PVDF

Electrical data for the diaphragm breakage sensor

a) Switch contact

30 V DC/1 A

or 125 V AC/0.6 A

or 250 V AC/0.3 A

The diaphragm sensor is a N/C relay.

IMPORTANT

Before commencing operation, install the provided diaphragm breakage sensor together
with the gasket (Item159) and make the electrical connections.

NOTE

• For safety reasons it is advisable to connect a safe low voltage (e.g. EN 60335-1 (SELV)).

• The cable priority is arbitrary.

b) Namur sensor, intrinsically

5-25 V DC, Namur type and/or DIN 19234, zero volt design.
Rated voltage: 8 V DC (R

i

~ 1 kΩ)

Power consumption:

Active surface, uncovered > 3 mA
Active surface, covered

< 2 mA

Rated switching distance: 1.5 mm
The monitor/feeder must be capable of evaluating current changes in order to indicate
diaphragm rupture!

WARNING

• EX-pump only: Installations in potentially explosive atmospheres must be inspected by

an “accredited qualified” person. This applies in particular also for intrinsically safe
electrical circuits.

• EX-pump only: observe documents supplied with the sensor!

IMPORTANT

• Before commencing operation, install the provided diaphragm breakage sensor together

with the gasket (Item159) and make the electrical connections.

• For pump without EX protection: For safety reasons it is advisable to connect a safe low

voltage (e.g. EN 60335-1 (SELV)).