Alarm Settings (ALARM)

40

8

Use the joystick lever (xy) to select [DURATION]
and use the lever (vw) to select the interval after
which the next alarm becomes in effect.

When an alarm is detected, another alarm signal will not be
output until the duration specified in this setting has passed.

Available settings: 5S, 10S, 15S, 20S, 30S, 45S, 1M, 2M,

3M, 4M, 5M (S: Second, M: Minute)

Memo: The interval setting for the next alarm to become in effect is

applied to the external switch whose number is the same as
the alarm input number. The alarm input from other external
switches will be accepted.

After completing setting, use the lever to move the cursor to
[MENU] and select “BACK” or “END”.

The ALARM OUT screen allows you to perform the alarm output
settings for each alarm output number.

1

Use the joystick lever (xy) to select [ALARM OUT],
use the lever (vw) to select an alarm output number
(1- 2), and press the [ENTER] button.

The ALARM OUT screen appears.

2

Use the joystick lever (xy) to select [OUTPUT] and
use the lever (vw) to select an alarm output option.

Available settings:

• OFF:

Does not output the alarm signal.

• ON:

Outputs the alarm signal.

• REMOTE: Outputs the alarm signal by remote operation.

(This option is available only when [ALARM
OUT] is set to “2”.)

3

Use the joystick lever (xy) to select [POLARITY]
and use the lever (vw) to select the polarity for the
alarm output signal.

Available settings:

• NO (Normal Open):

Normally open so closed condition is detected as output.

• NC (Normal Close):

Normally closed so open condition is detected as output.

4

Use the joystick lever (xy) to select [ALARM TIME]
and use the lever (vw) to select a duration for which
the alarm signal is output.

The connected devices such as recorder, alarm buzzer and
warning lamp will operate for the duration you have specified.

Available settings: 2S, 5S, 10S, 15S, 20S, 30S, 45S, 1M,

2M, 3M, 4M, 5M, MANU
(S: Second, M: Minute)

Memo: “MANU” appears only when “REMOTE” is selected for

[OUTPUT] in step 2.

After completing setting, use the lever to move the cursor to
[MENU] and select “BACK” or “END”.

The alarm output duration when using remote operation depends on
the setting for [ALARM TIME].

• When selecting the value between “2S” and “5M”:

Outputs the alarm for the duration you have specified.

• When selecting “MANU”:

Controls the alarm output duration by the AUX6 operation
(ON/OFF) from external device.

• When the alarm input is used as the external control

input of the Day/Night function, “D/N” appears in the
top right of the screen. In this case, settings other
than [POLARITY] cannot be made.

• When multiple alarm inputs are received

simultaneously, the input whose alarm number is
smaller precedes the others.

B Setting the alarm output (ALARM OUT)

ALARM

y
y


ALARM IN
ALARM OUT
ALARM DISABLE

MOTION
ALARM DISPLAY

PRESET
MENU

1
1
OFF

OFF
OFF

OFF
BACK

ALARM OUT 1


OUTPUT
POLARITY
ALARM TIME





PRESET
MENU

ON
NO
5S

OFF
BACK

• When selecting “REMOTE”, “MANU” is

available for [ALARM TIME] enabling the
manual operation of the alarm output.

• When selecting “REMOTE”, the alarm signal

will not be output automatically even when the
alarm is detected.

The alarm output duration for remote operation

While the alarm is output using remote operation, normal
alarm output cannot be used.

L5BU2_XE(VCC-MC600P_MC500P)(GB).book 40 ページ 2007年1月18日 木曜日 午前9時44分

Advertising
This manual is related to the following products: