Appendix b: control panel protocol, Commands – Sennheiser CONFERENCE SYSTEM SDC 8000 User Manual

Page 112

Advertising
background image

Appendix B: Control panel protocol

112

Appendix B: Control panel protocol

The SDC 8000 conference and interpretation system supports a control
panel. The central unit sends a control command to the connected control
panel:

y when a delegate or chairman unit is activated,
y when a delegate or chairman unit is deactivated,
y a microphone goes into request mode,
y when all active microphones are deactived simultaneously

(priority function).

The control panel sends a control command to the central unit:

y when a delegate or chairman unit is to be activated,
y when a delegate or chairman unit is to be deactivated,
y when the control panel is to be reset (Reset)

The control panel must be connected to the SDC 8000 CU central unit’s
COM 2 interface (RS 232 connection). The settings for the communications
port for the control panel are:

Bits per second: 19,200

Data bits:

8

Parity:

None

Stop bits:

1

Flow control:

None

Note!

In order to connect a control panel to the central unit, you have to
purchase the serial output license SDC 8000 S-SO (Cat. No. 9855)

Commands

All commands sent by the SDC 8000 CU central unit start with a “%” sign.
The last character is a character which states the end of the transmission.
Just before the end-of-transmission character, there are four characters
within the command sent to the camera control which account for the CRC
checksum.

The CRC checksum is in uppercase hexadecimal form while all other
numbers are in decimal form.

STX “%”

data

CRC

ETX

Start of
Transmission
Character
(0x25 = “%”)

Data of the
command

16 bit sum of the
ASCII characters
between STX and
CRC

End of
Transmission
Character
(0x0D)