See “enabling – Sennheiser CONFERENCE SYSTEM SDC 8000 User Manual

Page 89

Advertising
background image

Configuring the SDC 8000 system

89

̈

Choose “

B-channel

” and press the ENTER key.

A booth number is shown on the display.

̈

Choose the number of the booth whose main target language
corresponds to the language you want to configure for the B-channel.

Example:

Let us assume that there are three interpreter booth:

y Booth

1

for the target language

English

y Booth

2

for the target language

French

y Booth

3

for the target language

German

In order to set the B-channel of booth 3 to English, choose “

1

” from the

B-channel

” menu.

Enabling the auto-relay interpretation function (Auto-floor)

If the original floor language is a language of which all interpreters have a
complete understanding and from which they work, you

do not

have to

enable this function. In this case, all interpreters interpret the original floor
language into their respective target languages. These interpretations are
then fed to the corresponding interpretation channels.

If the original floor language is

not

a language of which all interpreters

have a complete understanding and from which they work, you can enable
the auto-relay interpretation function (auto-floor): The original floor
language is interpreted into a language understood by all interpreters.
This interpretation is automatically “relayed” to the floor channel of all
other interpreters and serves as the basis from which they interpret into
their respective target languages.

To enable the auto-relay interpretation function (auto-floor):

Attention!

The interpreter who delivers the relay interpretation has to choose the

B-channel

!

̈

From the central unit’s operating menu, choose “

Interpretation

”,

Configuration

” and “

Select Booth

” one after the other.

The current booth number is shown on the display.

̈

Choose the number of the booth from which the relay interpretation is
to be delivered and press the ENTER key.

̈

Choose “

Auto-floor

” and press the ENTER key.

̈

Choose “

Yes

” to enable the auto-floor function and press the ENTER

key to save this configuration.
The relay interpretation is automatically “relayed” to the floor channel
of all other interpreter consoles and the AUTOFLOOR LED

on these

interpreter consoles lights up, indicating that the auto-floor function is
enabled.

Booth Configuration
2 B-channel

Booth Configuration
3 Auto-floor

1.

Booth Configuration

Auto-floor = Yes
Press ENTER to Save

©

Advertising