Unit Not Steaming Properly in Steam Mode or Combi Mode

Unit Not Steaming Properly in Steam Mode or Combi Mode.

Check water pressure at unit with unit running.

Disconnect plug PL20 (plug PL3 for ovens built before

March 1, 2002) and place test leads in harness side of plug.

Operate unit in steam mode. Wait until steam mode LED

stops flashing. Check voltage.

Does voltage

rise and fall from 0 to

approximately

24 volts?

Turn unit off. Remove

right side exterior cover

from unit, if desired.

Is resistance

between 1 and 10

megaohms?

Replace

solenoid valve.

Turn-off water supply to unit. Remove

water-supply copper tube from

compression fitting at inlet to solenoid

valve inside unit. Attach one end of 1/4"

ID hose to tube and place other end in

drain or bucket. Turn water supply on.

No

Yes

No

Yes

Significant

water flow

(>1/2 gpm)?

Remove screen from

strainer on back of unit.

Clean or replace screen.

Remove solenoid valve and

flow regulator. Examine for

deposits or debris that would

impede water flow. Clean and

replace as necessary.

No

Yes

Check wiring.

Replace board.

Check solenoid valve

coil resistance.

Unit steaming

properly?

Replace pressure

regulator on back of unit.

Finished

No

Yes

Turn unit on in steam

mode.

Advertising