2-4 Installing the System into a Rack

This section provides information on installing the SuperServer 6015B-Ni into a

rack. If the 6015B-Ni has already been mounted into a rack, you can skip ahead

to Sections 2-5 and 2-6. There are a variety of rack units on the market, which

may mean the assembly procedure will differ slightly. The following is a guideline

for installing the 6015B-Ni into a rack with the rack rails provided. You should also

refer to the installation instructions that came with the rack unit you are using.

Identifying the Sections of the Rack Rails

You should have received two rack rail assemblies with the SuperServer 6015B-Ni.

Each of these assemblies consist of three sections: an inner fi xed chassis rail that

secures to the 6015B-Ni (A) and an outer fi xed rack rail that secures directly to the

rack itself (B). A sliding rail guide sandwiched between the two should remain at-

tached to the fi xed rack rail. (See Figure 2-1.) The A and B rails must be detached

from each other to install.

To remove the fi xed chassis rail (A), pull it out as far as possible - you should hear

a "click" sound as a locking tab emerges from inside the rail assembly and locks

the inner rail. Then depress the locking tab to pull the inner rail completely out.

Do this for both the left and right side rack rail assemblies.

Figure 2-1. Identifying the Sections of the Rack Rails