Installing the server into a telco rack – SUPER MICRO Computer 6015B-Ni User Manual

Page 23

Advertising
background image

Chapter 2: Server Installation

2-7

Figure 2-4. Installing the Server into a Telco Rack

Installing the Server into a Telco Rack

To install the SuperServer 6015B-Ni into a Telco type rack, use two L-shaped

brackets on either side of the chassis (four total). First, determine how far follow

the server will extend out the front of the rack. Larger chassis should be positioned

to balance the weight between front and back. If a bezel is included on your

server, remove it. Then attach the two front brackets to each side of the chassis,

then the two rear brackets positioned with just enough space to accommodate the

width of the telco rack. Finish by sliding the chassis into the rack and tightening

the brackets to the rack.