Controller mode – Samsung SCC-3000 User Manual

Page 27

Advertising
background image

《27》

Controller Mode

(2) Controller ID Setup

■ This menu is for setting controller ID.

① At the [Controller SETUP 1 ▶] menu, press the 1 button (see p.26).

② Press a number on the number pad to enter a controller ID.
③ Press the ENTER button to set the controller ID.

▤ Assign number 1 for setting the controller ID for the master controller.
▤ The lower the ID number, the higher the controller priority.
▤ Sub-controllers can be operated only when connected to a master

controller; Sub-controllers cannot be operated independently.

CONTROLLER SETUP1

1:CONTROLLER ID

2:SERIAL

3:COPY

Press Numeric Key

(3) SERIAL Setup

■ This menu is for setting the serial port for connecting external devices to the controller.

① At the [Controller SETUP 1 ▶] menu, press the 2 button (see p.26).

② Press the 1 button to activate the Serial 1 PORT Setup screen (PTZ

camera/DVR connection PORT). Press the 2 button to activate the
Serial 2 PORT Setup screen (reserved PORT).

▤ The value displayed at step ② indicates the current setup value.
▤ The BAUD RATE/ DATA BIT/ STOP BIT/ PARATY BIT for PORT

2, which connects to the sub-controller, are fixed and cannot be
changed.

③ The PORT Setup screen will be displayed.

Press the number for a setup menu.

1: Sets the BAUD RATE. (4800, 9600, 19200, 38400)
2: Sets the DATA BIT. (8BIT, 7BIT)
3: Sets the STOP BIT. (1BIT, 2BIT)
4: Sets the PARITY BIT. (NONE, ODD, EVEN)

▤ Default values for controller SERIAL are 9600 (BAUD RATE), 8BIT

(DATA BIT), 1BIT (STOP BIT) and NONE (PARITY BIT).

CONTROLLER SETUP1

1:CONTROLLER ID

2:SERIAL

3:COPY

Press Numeric Key

RS-422/485 SET

1:S1 9600, 8, 1, NONE

2:S3 9600, 8, 1, NONE

Press Numeric Key

RS-422/485 SET

1:BUAD

3:STOP BIT

2:DATA

4:PARITY

Press Numeric Key

Enter:ID Set <1-16>

CONTROLLER ID SET

CONTROLLER ID:

1[

0 ]

ID 1 IS MASTER ID!

Advertising