X-rack installation – Solid State Logic X-Logic Series User Manual

Page 10

Advertising
background image

Page 6

X-Rack Owner’s Manual

3. X-Rack Installation

3.1 Assembling the X-Rack

The X-Rack unit is normally shipped either as an empty rack (SSL Part No. 729935X1), a part filled (custom)

rack or as a fully loaded unit; for example, a unit fitted with eight 729618X1 Dynamics modules (SSL

Part No. 729935X2) – if you have purchased a fully loaded unit you should skip the rest of Section 3.1.
In the case of empty or part filled racks, any empty module slots will be covered by blank panels which

will need to be removed before fitting additional modules.

Note. Do not attempt to fit or remove modules with power applied. Always switch the rack off and remove the power cord

prior to working on this unit. When fitting or removing modules, it is advisable to observe suitable ESD precautions.

Take care when handling modules and blank panels; sharp corners may be present.
Modules are fitted from the front of the X-Rack, normally starting from the left hand end. Note that it is

recommended that any required blank panels (SSL Part No. 729618X2) are fitted prior to fitting modules.

Each module plugs into the backplane; use the two 8mm M3 counter sunk screws supplied with the

module or blank to fix the item to the front of the rack – a 2mm AF hex key is supplied with the X-Rack

unit. The rear connector panel or blank should be screwed to the rear of the case using the two 8mm M3

button head screws supplied with the module. The end result should be a unit that is fully loaded with

modules and/or blank panels. For ease of fitting, do not tighten the screws until all modules and/or blank

panels have been fitted.

Note. To ensure peak operating performance, please ensure all rear panel fixing screws are securely tightened; warping on

the rear of the chassis may be observed – this is no cause for concern.

3.2 Mounting

The X-Rack unit is designed to be rack mounted or free standing. It is 4RU (178mm/7 inches) high. Its

depth is:

180 mm/7.2 inches

255 mm/10.2 inches including connectors

The unit does not require rack shelves. A 1RU space should normally be provided above the unit.
The unit is supplied fitted with both feet and rack ears. If the unit is to be rack mounted the feet should be

removed using the supplied 2.5 mm AF hex driver. The same driver can be used to remove the rack ears

if the unit is to be free standing.

Feet and rack ears are fixed using M4 x 8mm screws.

Do not replace them with longer screws as this may damage the rack electronics.