Page 12

X-Rack Owner’s Manual

• The display will show ‘5a’ and both the ‘SAVE’ LED and display flash.

• Create an additional MIDI track in your DAW program. Select its input and output to be the MIDI port

connected to your X-Rack.

• If available select the track to store System Exclusive data and record enable the MIDI track.
• Press Play and Record on the DAW to put the MIDI track into record.
• Press the SAVE switch to start transmission of all saved Total Recall setups.

A ‘rotatingsegment’ display will start and run until all data has been transmitted

• Once the display changes to ‘m1’ stop the DAW to end recording.
An unlimited number of Total Recall setups can be stored in this way.
Loading Setups from a Mac or PC (l0)
Restoring setups from a Mac or PC is even simpler:
• Enter MIDI mode as before, and turn the D-Pot until the display

changes to ‘l0’ and begins to flash.

• Locate the DAW to just before the SysEx data containing the setups you wish to load.
• Play through the SysEx block of data. The display will show a rotating segment while data is received.

As soon as the X-Rack detects the start of valid data it will delete all the current setups and replace them

with the stored ones from the MIDI track.

4.4.3 Write Protect Mode (pr)

Write Protect prevents existing stores being over

written or deleted, providing an extra level of

protection for units that have been programmed

with particular settings.
When set to ‘0n’ the Save and Delete functions are

disabled. When set to ‘0f’ they are enabled. The

Wr Prot’ LED lights to show this mode has been

selected.

4.4.4 Remote Mode (re)

This mode enables remote

control of X-Rack, either from an

AWS 900 for saving and

recalling Total Recall snapshots

or from a MIDI controller for control of the XR622 Master module.
When Remote Mode is ‘0n’, selecting a TR setup on the AWS 900 Total Recall page will change the current

X-Rack setup to the one saved in the AWS 900. The X-Rack display will change to read ‘re’ (remote).

Pressing the D-Pot will display the TR setup as normal. When Remote Mode is ‘0f’, turning the D-Pot will

change the current X-Rack setup to one of the internal stores but when Remote Mode is set to ‘0n’ the D-

Pot is disabled once the X-Rack has received a setup from an AWS 900. This also prevents saving or