The Total Recall computer stores all of the switch and rotary control

positions for each X-Rack module in one of thirty two internal stores.

These can be recalled and compared with the current settings using

front panel LEDs to show which controls do not match. If the module

layout has changed since the snapshot was taken, only the modules

that match will be recalled.
The contents of all the stores can be archived and restored as a MIDI

system exclusive data dump.
Additionally the X-Rack can interface with the Total Recall system on

an AWS 900 or AWS 900+. This allows the settings of up to three X-Rack

units to be stored along with the AWS 900 settings.

Note. Through the rest of this manual, references to ‘AWS 900’ apply equally to

‘AWS 900+’.

4.2 Stand-alone Mode

4.2.1 Saving Stores to Internal Memory

A maximum of 32 stores can be saved in internal non-volatile memory, provided the stores have not been

write-protected – indicated by the ‘Wr Prot’ LED

being illuminated.

First select a store by turning the D-Pot

, then press SAVE

to

store all of the current control positions.
If the store has already been used the SAVE LED will flash. Press the

SAVE

switch a second time to overwrite the store.

4.2.2 Recalling and Displaying Stores

To select a store using the D-Pot

then press the D-Pot to select that store.

The current store is displayed on the dual 7-segment display

.

If the selected store is empty the ‘Empty’ LED

lights and the unit will not switch to display mode.

With a valid store selected, the X-Rack module SEL LEDs will light if the module type in the store (EQ,

Dynamics etc.) matches the module currently fitted in that slot. A flashing SEL LED indicates that some controls

on that module do not match the stored positions. A steady LED shows that all controls are matched. The

switch LEDs will light if the current switch position does not match the stored positions. Press or release

the switch as required to extinguish the LED.
Above each rotary control is a bi-colour LED:

The LED extinguishes when the control matches the stored position.
If a store is already being displayed when you select a different store the display will flash and the new

store will not become active until you press the D-Pot for a second time.

4.2.3 Exiting Display Mode

Push the D-Pot

a second time to exit display mode.

All SEL LEDs will extinguish and the channel switch LEDs will now show the position of their respective

switches.

4

The LED lights red if

the control needs

turning anti-clockwise.

or

The LED lights green if

the control needs

turning clockwise.

2

1

4

5

4

5

Push to Select

SAVE

3

SETUP/

MIDI

SAVE

Push to Select

COPY/

DEL

TOTAL RECALL

Empty

Wr Prot

1

7

6

5

4

3

2

Advertising