Solid State Logic X-Logic Series User Manual

Page 36

Advertising
background image

Page B-6

X-Rack Owner’s Manual

LF EQ - Maximum Gain

Adjustment:

1. Set LF Gain to maximum and select LF

. Set the audio oscillator for

80Hz and adjust LF Frequency to find the maximum level on the audio
level meter.

2. Adjust VR14 (LF Q) for +16.5dBu ±0.25dB.

3. Reset LF Gain to its centre indent position, de-select LF

and re-check

the audio level meter for 0dBu.

B.4.2 Output Balance

Equipment Required:

Calibrated audio oscillator, audio level meter and a ‘balance’ adaptor (see
below).

Test Signal:

1kHz sine wave at +24dBu.

Input and Output:

Oscillator to the Input of the channel being tested, Output to the level
meter via the ‘balance’ adaptor.

Unit Setup:

Ensure that all front panel switches are off and all controls are set fully
anti-clockwise.

Adjustment:

Connect the test equipment to the each channel in turn and adjust VR15
(BAL) for minimum level (< 55dBr).

B.4.3 ‘Balance’ Adaptor

For the output balance adjustment, a ‘balance’
adaptor such as that illustrated here will be
required. This adaptor consists of a pair of close
tolerance resistors in an in-line cable and is
used to sum together a balanced output in
order to correctly adjust the level balance of the
measured output; perfect balance should result
in complete signal cancellation.

5K01**

5K01**

2

3

1

2

3

1

0V

+

0V

+

To measuring
equipment

From unit

under test

1

2

1

Resistor tolerance should ideally be 0.01%
Absolute level measured will depend upon the input
impedence of the measuring equipment.