Solid State Logic X-Logic Series User Manual

Page 34

Advertising
background image

Page B-4

X-Rack Owner’s Manual

LMF Band controls:

Frequency

Variable from 200Hz to 2.5kHz

Gain

Variable by > ±20dB

‘Q’

Variable from 0.5 to 2.5 (may also vary with gain)

LF Band controls:

Frequency

Variable from 40Hz to 600Hz

Gain

Variable between ±16.5dB

‘Q’

2.5 (on ‘

’ setting)

The LF and HF bands have variable turnover frequency with switchable bell/shelving and selectable
response curves:

• Normal (‘E type’) curves with the ‘G-EQ’

switch OUT follow conventional cut or
boost characteristics.

• ‘G type’ curves with the ‘G-EQ’ switch IN,

have a modified slope with a degree of
overshoot/undershoot for increased
selectivity.

The two parametric bands have selectable characteristics which affect the relationship between frequency
bandwidth and gain:

• With the ‘G-EQ’ switch OUT, the frequency

bandwidth is constant at all gains.

• With the ‘G-EQ’ switch IN, the frequency

bandwidth reduces with increased gain,
thereby increasing the selectivity of the EQ
as the gain is increased.

• At full boost or cut both are identical.

10

100

1k

10k

20k

-25.0

-20.0

-15.0

-10.0

-5.0

0.0

5.0

10.0

15.0

20.0

25.0

Amplitude (dBr) v Frequency (Hz)

Channel Equaliser Curves

’G type’

’E type’

Both

0.0

25.0

-25.0

20

100

1k

10k

100k

-20.0

-15.0

-10.0

-5.0

5.0

10.0

15.0

20.0

Amplitude (dBr) v Frequency (Hz)

Channel Equaliser Curves

’G type"

’E type’

Advertising