X-Rack Owner’s Manual

A.2.3 HF/LF Section

This section contains simple high and low pass filters as follows:

HF (Low Pass):

Frequency range 50kHz – 3kHz (–3dB point)
Slope: 12dB/Octave

LF (High Pass):

Frequency range 30Hz – 600Hz (–3dB point)
Slope: 18dB/Octave

The two filters can be switched into circuit independently.

A.2.4 OUTPUT Section

This small section contains a tri-colour signal present indicator and two routing
switches (‘REC L’ and ‘REC R’) which route the module signal onto a common
internal record bus.

The signal present indicator measures signals immediately prior to the output
amplifier. It will light GREEN for output signals above the lower threshold of
–60dBu, AMBER for signals between +4dBu and +24dBu and lights RED for signals
above +24dBu.

The record bus is not currently used but may be used by forthcoming X-Rack
modules (such as the XR622 Mix/Monitor Module, due late 2006).