This Instrument

• Do not subject this instrument to strong impact or vibration.
• Do not forcibly pull, bend, or apply strong force to power cord for attached AC adapt-

er or USB cable. This may result in snapping.

• Connect this unit to power source with minimal noise.
• Should breakage or abnormality be found during operation, switch power off immedi-

ately and unplug. Then refer to "Error Check" on page 111.

• Should this instrument break down, do not try to disassemble and repair it by your-

self. Please contact the nearest KONICA MINOLTA SENSING authorized service facil-
ity.

• Warm this instrument up for 15 minutes at least after switching power on when the

luminance is 10 cd/m

2

or lower (measuring angle 1˚). This helps to improve the mea-

suring accuracy.

Backup Battery

• Measurement data and settings are stored in memory which is backed up by internal

backup battery. Backup battery is charged during operation of this instrument, and
can retain memory content for 3 months if it has been fully charged. At the time of
purchasing, battery may have already been partially discharged, so switch power on
to charge. Battery can be fully charged in 20 hours. Overcharge does not have to be
worried about in this case.

• Do not replace internal backup battery (Type: ML2030 3V) by yourself. Please contact

the nearest KONICA MINOLTA SENSING authorized service facility.

• We recommend that you should backup important data with data management soft-

ware CS-S10w Standard Edition as standard accessories to store separately.

Objective and Close-Up lenses (Optional)

• Make sure that surfaces of objective and close-up lenses are clear. Correct measure-

ment may not be performed if there is dirt, dust, hand soil or part left unclean.

• Do not touch surface of objective or close-up lens with hand.
• Do not change ambient temperature rapidly under high humidity. This may mist lens,

resulting in incorrect measurement.

Recommended batteries

• Batteries themselves give poor performance at low ambient temperature, which

should cause to decrease the measurement frequency. For power source of this
instrument, we recommend that you should use the lithium or nickel metal hydride
batteries that are hardly affected by temperature change at low ambient temperature.