5. Grasp a blotter strip and carefully pull it off the transport. Discard the

soiled strips.

6. Install the new blotter strip. Make sure that you align it in the transport

channel before pressing the adhesive side into the channel.

7. Re-insert the horizontal belt module.

8. Lower the horizontal transport plate.

9. Close the swing out door.