RETEST AFTER REPAIR

Retest a machine:

• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the

machine’s electrical characteristics. OR

• If you repair or replace any electrical components.

IDLE AMPS

Input Volts

Maximum Idle Amps

50 – 113 VDC

1 Amp

OPEN CIRCUIT VOLTAGES

Mode

Input Voltage

Open Circuit Voltage

CC Stick

72 – 113 VDC

74 – 78 VDC

CC Stick

60 – 72 VDC

Volts In + 4 VDC

CC Pipe (200 A preset)

72 – 113 VDC

73 – 78 VDC

CV Min. Preset

60 – 113 VDC

17 – 20 VDC

CV Max. Preset

60 – 113 VDC

50 – 54 VDC

LOAD TEST

Mode

Input Voltage

Output Amps and Volts

CC Stick/Gouge

60 – 113 VDC

100 Amps @ 24 VDC

CC Stick/Gouge

60 – 113 VDC

200 Amps @ 28 VDC

CC Stick/Gouge

60 – 113 VDC

350 Amps @ 34 VDC

FAN AS NEEDED (F.A.N.)

The fan should turn on when the machine is loaded and stay on for 50–70 seconds after the output load is
removed.