CLAMP

BRACKET

ANALOG CONTROL
SUPPLY PC BOARD
(4 SCREWS)

SCREWS (2)

CHOPPER
PC BOARD

CAPACITOR
POSITIVE
STRAP

CAPACITOR
NEGATIVE
STRAP
LEADS

+

-

RIGHT
SIDE

LEFT
SIDE

#X4A
#X1A

#X4
#X1
#401
#401A

FIGURE F.13 – POWER CAPACITOR MOUNTING DETAILS

POWER CAPACITOR REMOVAL AND REPLACEMENT (CONTINUED)

PROCEDURE

Refer to Figure F.13.

1.

Set the CC/CV power switch to OFF.

2.

Remove input power to the machine.

ELECTRIC SHOCK can kill.

Disconnect input power before removing the
case cover and performing tests or making
repairs to the machine.

3.

Perform the Case Cover Assembly
Removal
procedure.

4.

Perform the Power Capacitor Discharge
procedure.

5.

Disconnect the two plug harness connec-
tions at the top of the tunnel assembly.

6.

Disconnect the plug harness connection
above each Chopper PC board.