TROUBLESHOOTING & REPAIR

F-32

F-32

MULTI-WELD 350

NORMAL WELD VOLTAGE WAVEFORM

MACHINE LOADED TO 350 AMPS AT 34 VOLTS – CV MODE

This is the typical CV output voltage
generated from a properly operating
machine. Note that each vertical divi-
sion represents 50 volts and that each
horizontal division represents 50µs in
time.

The machine was loaded with a resis-
tance grid bank to 350 amps at 34
volts.

SCOPE SETTINGS

Volts/Div.....................50V/Div.
Horizontal Sweep .....50µs/Div.
Coupling.............................DC
Trigger.........................Internal

50V

50µs

0 volts

Advertising