Accessories, Caution – Lincoln Electric MULTI-WELD SVM151-A User Manual

Page 25

Advertising
background image

CONNECTION OF THE LN-25 TO THE
MULTI-WELD 350 “ACROSS THE ARC”
(SEE FIGURE C.1.)

1.

Shut the welder off.

2.

Connect the electrode cable from the LN-25 to the
“+” terminal of the welder.

NOTE: Welding cable must be sized for current and
duty cycle of application.

3.

Attach the single lead from the LN-25 to the work
using the spring clip on the end of the lead. This is
only a sense lead – it carries no welding current.

If you are using an LN-25 without an internal contactor,
the electrode will be “HOT” when the Multi-Weld 350 is
turned ON.

4.

Set the MODE switch to “CV.”

5.

Adjust wire feed speed at the LN-25.

6.

Adjust the HOT START CONTROL to the desired
level. (Use “O” for fine wire.)

7.

Set VOLTMETER switch to the positive position.

C-3

C-3

ACCESSORIES

MULTI-WELD 350

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

AMPHENOL

TO WORK

WORK CLIP LEAD

LN-25

WIRE FEEDER

OPTIONAL K444

REMOTE CONTROL

TO WORK

ELECTRODE

6 PIN

TO WORK

CAUTION

FIGURE C.1

MULTI-WELD 350/LN-25 ACROSS THE ARC CONNECTION DIAGRAM