REMOTE OUTPUT CONTROL OPTIONS

The Multi-Weld 350 is provided with a 6-pin remote
receptacle to permit use with the 25 ft.(7.6 m) K857 or
100 ft. (30.4 m) K857-1 Remote Output Control
options. The remote receptacle can also be used with
the LN-25 equipped with the K444-1 Remote Control
option. These remotes have single-turn resolution on a
Minimum to Maximum numbered dialplate.

CV MODE WIRE WELDING

The Converter in CV mode was designed for use with
an arc-powered wire feeder like the LN-25. The
Converter output is always “hot” when the mode switch
is not OFF. Therefore it is recommended that the LN-
25 model be equipped with the internal contactor in
order to have a “cold” electrode when the gun trigger is
released.

The CV mode recommended processes are positive
(+) polarity wire welding within the output capacity of
the Converter, including:

Flux Cored Arc Welding (FCAW)

Innershield:

NS3M (5/64-3/32)
NR305 (.068)

Outershield:

OS-70 (1/16-5/64)
OS-71 (.045-1/16)

MC-710 (.045-5/64)

Gas Metal Arc Welding (GMAW)

Carbon Steel: L50/56 (.030-1/16)

CC MODE STICK WELDING
AND GOUGING

The CC mode recommended processes are positive
(+) polarity stick and arc gouging within the output
capacity of single, or paralleled, Converters, including:

Shielded Metal Arc Welding (SMAW)

E6010/6011:

FW5P/180 (3/32-1/4)
“fast-freeze”

E6013:

FW37 (3/32-3/16)
“fill-freeze”

E7010/8010:

SA85/70+ (3/32-7/32)
“fast-freeze” HT pipe

E7018/7028:

JW LH70/3800 (3/32-5/32)
“low-hydrogen”

E7024/6027:

JW1,3/2 (1/8-5/16)
“fast-fill”

Arc Air Carbon (AAC)

Gouging:

Carbons (5/32-3/8)

B-5

B-5