Symptoms, Major physical or electrical damage is evident, Troubleshooting & repair – Lincoln Electric MULTI-WELD SVM151-A User Manual

Page 44: Caution

Advertising
background image

Observe Safety Guidelines

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely,
contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
1-800-833-9353.

PROBLEMS
(SYMPTOMS)

POSSIBLE AREAS OF
MISADJUSTMENT(S)

RECOMMENDED
COURSE OF ACTION

OUTPUT PROBLEMS

Major physical or electrical damage
is evident.

1.

Contact your local Lincoln
Authorized Field Service
Facility.

1.

Contact the Lincoln Electric
Service Department at 1-800-
833-9353 (WELD)

The Multi-Weld 350 is completely
dead. The meters do not light and
the input contactor does not acti-
vate when the ON/OFF Mode
Selector switch is turned on.

1. Make sure the power source is

working properly and supplying
at least 50VDC to the Multi-
Weld 350. The electrode cable
must be positive polarity and the
work cable negative polarity.

2. Check the electrode and work

cables for loose or faulty con-
nections.

1. Measure the input voltage to the

Multi-Weld 350. It must be
between 50 and 113VDC.

2. The ON/OFF Mode Selector

switch (S1) may be faulty.
Check and replace if faulty. See
the Wiring Diagram. Also check
associated wiring.

3. The input diode D1/D2 may be

open. Check. See the Wiring
Diagram.

4. Perform the DC Buss Supply

Board Test.

5. Perform the Analog Control

Power Supply Board Test.

6. The Weld Control Board may be

faulty. Replace.