SETTING ARC SENSING WIRE FEED SPEED FOR
CONSTANT CURRENT OPERATION

When using a constant current (formerly variable voltage)
power source, welding performance is improved using arc
sensing wire feed speed (CC operation). In this wire feed
mode the wire speed increases if arc voltage increases, and
decreases if arc voltage decreases, but remains constant at
any specific voltage level.

The LN-15 permits accurate presetting of the desired
wire feed speed, for the desired arc voltage to be used,
by setting the Wire Feed Speed in the following manner
before welding:

a. Activate press and spin during power up and change

to the CC mode. See “Changing the CV/CC mode
or WFS units” in this Operation Section.

FIGURE B.4 CC WIRE SPEED SETTING

b. Referring to the graph located above the Mode switch

(also shown in Figure B.4):

1. Select the horizontal line representing the DE-

SIRED IN/MIN. for the welding procedure. (See
example arrow line for 375 in/min.)

2. Select the diagonal line representing the ARC

VOLTS to be used for the welding procedure. (See
example arrow line for 29 volts.)

3. Determine the vertical line representing the CC

WIRE SPEED SETTING where the above two lines
cross. (See example arrow line for 450.)

c. Adjust the WFS display to the value determined in

Step (3) above (450 for example used).

The wire will feed at the DESIRED IN/MIN speed when the welding
power source is set to the arc voltage to be used for the weld
procedure (375 in/min. at 29V for example used).

The CC wire speed setting graph is shown in TABLE B.1, giving

the Wire Speed dial setting required for the DESIRED IN/MIN
and ARC VOLTS used for the welding procedures:

TABLE B.1 CC WIRE SPEED SETTING

Arc Volts Used

Desired

In/Min

16 18

20

22 24 26 28 30 32 34

50

109

97

88

80

73

67

63

58

55

51

60

131

117

105

95

88

81

75

70

66

62

70

153

136

123

111 102

94

88

82

77

72

80

175

156

140

127 117 108 100

93

88

82

90

197

175

158

143 131 121 113 105

98

93

100

219

194

175

159 146 135 125 117 109 103

110

241

214

193

175 160 148 138 128 120 113

120

263

233

210

191 175 162 150 140 131 124

130

284

253

228

207 190 175 163 152 142 134

140

306

272

245

223 204 188 175 163 153 144

150

328

292

263

239 219 202 188 175 164 154

160

350

311

280

255 233 215 200 187 175 165

170

372

331

298

270 248 229 213 198 186 175

180

394

350

315

286 263 242 225 210 197 185

190

416

369

333

302 277 256 238 222 208 196

200

438

389

350

318 292 269 250 233 219 206

210

459

408

368

334 306 283 263 245 230 216

220

481

428

385

350 321 296 275 257 241 226

230

503

447

403

366 335 310 288 268 252 237

240

525

467

420

382 350 323 300 280 263 247

250

547

486

438

398 365 337 313 292 273 257

260

569

506

455

414 379 350 325 303 284 268

270

591

525

473

430 394 365 338 315 295 278

280

613

544

490

445 408 377 350 327 306 288

290

634

564

508

461 423 390 363 338 317 299

300

656

583

525

477 438 404 375 350 328 309

310

678

603

543

493 452 417 388 362 339 319

320

700

622

560

509 467 431 400 373 350 329

330

642

578

525 481 444 413 385 361 340

340

661

595

541 496 458 425 397 372 350

350

681

613

557 510 471 438 408 383 360

360

700

630

572 526 484 450 420 394 370

380

666

604 554 512 472 444 416 392

400

700

636 584 538 500 466 438 412

420

668 612 566 526 490 460 432

440

700 642 592 550 514 482 452

460

670 620 576 536 504 472

480

700 646 600 560 526 494

500

674 626 584 546 514

520

700 650 606 568 536

540

676 630 590 556

560

700 654 612 576

580

676 634 598

600

700 656 618

620

678 638

640

700 658

660

680

680

700

700

CC Speed Setting = Desired IPM X 35

Arc Volts

Advertising