Maintenance, Warning safety precautions – Lincoln Electric LN-15 WIRE FEEDER SVM166-A User Manual

Page 30

Advertising
background image

D-2

D-2

LN-15

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

MAINTENANCE

ELECTRIC SHOCK can kill.

• Do not operate with covers

removed.

• Turn off power source before

installing or servicing.

• Do not touch electrically hot

parts.

• Turn the input power to the welding power

source off at the fuse box before working in the
terminal strip.

• Only qualified personnel should install, use or

service this equipment.

WARNING

SAFETY PRECAUTIONS

ROUTINE MAINTENANCE

Routine maintenance consists of periodically blowing
out the machine, using a low pressure airstream, to
remove accumulated dust and dirt from inside the
feeder.

PERIODIC MAINTENANCE

• Replace the drive rolls and inner wire guide when

they are worn.

• Replace the pig tail if the insulation is cut, abraded or

damaged.

CALIBRATION SPECIFICATION

All calibration is factory set on the LN-15.

To verify the wire feed speed:

• Assemble a .045 (1.2mm) drive roll kit into the LN-

15.

• Load a spool of .045 (1.2mm) electrode and thread

the electrode through the wire drive.

• Adjust the wire feed speed to 300 in/min

(7.62m/min).

• Press the COLD FEED switch and measure the

actual wire feed speed with a calibrated wire feed
speed tachometer.

• The measured wire feed speed should be within 2%

of the set value.

To verify the voltage display:

• Set the welding power source and LN-15 to a CV

procedure that gives steady "spray" transfer in the
arc.

• While a weld is being made, measure the voltage

from the feed plate to work.

• The displayed voltage on the LN-15 should be with-

in 2% of the measured value.

Advertising