ELECTRICAL DIAGRAMS

G-3

LN-15

SCHEMATIC - ENTIRE MACHINE - (G4198-1)

EN-1

70

S

O

L

ID

E

D

G

E

G4198-1

LN-15 (ACROSS THE ARC)

MACHINE SCHEMATIC

NONE

G4198

E. ENYEDY/KJ

E. ENYEDY

UNLESS OTHERWISE SPECIFIED TOLERANCE
MANUFACTURING TOLERANCE PER E2056

ON 2 PLACE DECIMALS IS ± .02

ON 3 PLACE DECIMALS IS ± .002
ON ALL ANGLES IS ± .5 OF A DEGREE

WITH PUBLISHED STANDARDS.

MATERIAL TOLERANCE (" ") TO AGREE

t

DO NOT SCALE THIS DRAWING

DRAWN BY:

DESIGN INFORMATION

ENGINEER:

APPROVED:

REFERENCE:

EQUIPMENT TYPE:

SUBJECT:

SCALE:

G419

8-1

MATERIAL
DISPOSITION:

APPROVAL
DATE:

PROJECT
NUMBER:

NA

CRM35166

1

PAGE ___ OF ___

1

ENGINEERING CONTROLLED
MANUFACTURER:

No

RELEASED A.03 FROM "X"

DOCUMENT
NUMBER:

DOCUMENT
REVISION:

THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OWNED BY LINCOLN GLOBAL, INC. AND MAY NOT BE DUPLICATED, COMMUNICATED
TO OTHER PARTIES OR USED FOR ANY PURPOSE WITHOUT THE EXPRESS WRITTEN PERMISSION OF LINCOLN GLOBAL, INC.

PROPRIETARY & CONFIDENTIAL:

A

05/27/2003

LN-15 ACROSS THE ARC MODEL

J1,J86

CAVITY NUMBERING SEQUENCE

(COMPONENT SIDE OF P.C. BOARD)

J81,J82

6

5

10

1

3

4

1

2

J85,J87

9

8

16

1

4

6

1

3

GENERAL INFORMATION

ELECTRICAL SYMBOLS PER E1537

COLOR CODE

B -

BLACK

W -

WHITE

R -

RED

U -

BLUE

J83,J88

J2,J47,J84

5

4

8

1

526C

-

+

CONTACTOR
300A 60%

250A 100%

WORK

CLIP

BOOST BOARD

2
1

6

3

4

5

J47

8
7

POS

527A

502

NEG

526A

67

21A

A

D

C

B

E

555

J3

554

556

552

553

GAS

SOLENOID

552

550

551

553

TRIGGER

CONNECTOR

578

507

559 (RED)

512

558 (BLK)

512

558

COLD INCH/

GAS PURGE

S1

555

554

556

WIRE FEED SPEED
CONTROL
POTENTIOMETER

21A

527

MOTOR /

GEARBOX

TACH.

67

7

2

1

8

4

3

W

B

B

J2

INPUT ELECTRODE

CABLE CONNECTION

GUN

TRIGGER

INPUT

83%

PROCEDURE

INPUT

320V, 150J

320V, 150J

.0047/.005 mfd,

1400VDC

1M ohms

6

5

21B

567

21

GND-A

1
2

3

MOV ASBLY

GND-B

150V, 300J

MOV ASBLY

501

2.6 VDC @ 50 in/min
27.4 VDC @ 700 in/min
8 sec average Current
limit = 3.5 Amps
(Limit is software set)

Measure B to U
120 Hz @ 50 in/min
1.6 kHz @ 700 in/min

15 VDC Tach Supply

6.5 VDC when gas flowing
Coil measures 21 ohms

83

% In

pu

t

Tr

ig

ge

r S

up

ply

Trigg

er

Inp

ut

The 83% procedure reduces the
WFS to 83% of the set point, but
no less than 50 in/min. It is used
most often when pipe welding.

Cold Inch
15 VDC when Inch OFF
0 VDC when Inch ON

15

VDC

Co

ld

In

ch

Gas

P

ur

ge

The display board communicates to the feedhead board through the SPI
bus. Only the power supply signals can be monitored during servicing.

The WFS always shows the present WFS.

The voltage display shows the voltage while welding, plus holds the
voltage for 5 seconds after the weld. It shows "- - -" when idle. A negative
"-" sign will automatically be shown when welding with reverse polarity
procedures.

All the LEDs, including those not used, will briefly light on power up. The
LED's not used are visible behind the nameplate when lit.

L11757-1

SPI DISPLAY

WFS Display

Voltage Display

Voltage LED

Not Used

RED

RED

RED

RED

YELLOW

DISPLAY P.C. BOARD

2

1

6

3 4 5

8

7

10

9

SHIELDED CABLE
DRAIN LEAD

J1

+

15

VDC

SPI

+

5 VD

C SPI

Sl

av

e S

ele

ct

Ch

ip S

ele

ct 1

Ch

ip

Se

lec

t 2

Ch

ip S

ele

ct 3

Ma

st

er I

n

S

la

ve O

ut

Ser

ial

C

loc

k

Ma

ster O

ut

S

lav

e

In

COM

N.A.

Schematic L11756-x

El

ec

tr

od

e Vol

ta

ge

Pigtail

Bussbar from input
stud to contactor

BRIDGE
RECTIFIER

The rectifier allows the LN-15 to
be powered either electrode
positive or electrode negative
without any switches for the
customer to set.

This large MOV
absorbs the
inductive energy in
the weld cables and
power source when
the contactor
opens.

Located in the control box next
to the Feedhead board.

General Notes:

x

Codes 10864,11033 & 11035 do not support the high/low speed gear
change. Only the high speed (1.8" diameter) gear may be used.

Error
Code

Description

Cause and Remedy

Err 0081

Average
motor Over-
current
shutdown

The wire drive has exceeded the current rating:
ƒ

10 amps for 0.5 seconds or

ƒ

3.5 amps for 10 seconds.

Wait 45 seconds for the error to reset.

Reduce the current load on the motor by:
ƒ

Verifying the electrode slides easily through the
liner of the gun.

ƒ

Reduce the spindle brake resistance.

ƒ

Reduce the amount of tension in the wire drive
pressure arm.

ƒ

Use only Lincoln electrodes.

Err 0086

Trigger
lockout

The voltage into the feed head board exceeds 150
VDC.

Some inverters and choppers may have spikes on the
output that charge the capacitors inside the LN-15
beyond limits. If this error occurs, lower the OCV of
the power source. It may be likely that a different
power source is required.

Boost

Circuit

Common

to '-' input

enabling

circuit

COM

ISOLATION
SWITCH (FET)

- INPUT

COM

+ I

N

P

U

T

COM

MOTOR SUPPLY

FEEDHEAD SUPPLY

- IN

P

U

T

R

U

15- 110 VDC

The boost board takes the weld voltage
and boosts it to 80VDC for the rest of
the LN-15. There are two supplies on
the boost board, one for the motor and
the other for the feedhead board. With
two supplies, even if the motor supply
should droop because of heavy loads,
power to the feed head board is not
affected.

80VDC or weld voltage,
whichever is higher

COM

POT Supply

Wiper

Wiper to COM
5 VDC at 700 ipm
0 VDC at 50 ipm

10K Ohms
3-1/2 turns

Coil measures 4.4 ohms.

0 VDC Open
2.3 VDC Closed
12 VDC coil
PWM Controlled

Model

Ranger 8,9

Classic

Ranger 250, 305

Commander 300,400,500

(Common Analog

Controls)

V350

(Common Digital

Controls)

DC-400, 600

Square Wave TIG

300/355

Miller Inverters

STT II

K1870-1,-2 Across
the Arc

ƒ Recommended

all CV operation.

ƒ Recommended for CV

operation. (Wire
Feed Module
Required)

ƒ Recommended for CV

operation.

ƒ Recommended for

CV operation.

ƒ Recommended

for CV and CC
operation.

ƒ Not recommended

for CC operation
because the
customer may
experience short
contactor life from
inductive nature of
the power source.

ƒ Recommende

d for CV
voltage sense
operation.

ƒ Not

recommended
for STT
operation.

Note:
Most semiautomatic
wire welding
processes perform
better using constant
voltage power sources.
Be sure the proper
power source is used
for your application.
Contactor life may be
shortened in
applications using CC
machines with high
OCV.

ƒ

Boost Board

Wire Drive
Circuit

Positive
Voltage
Feedback

Input
Power
Circuit

Input
Voltage
Protection

Contactor

WFS
Control
Circuit

Gun Trigger
Circuit

Inch/Purge
Circuit

Gas Solenoid
Circuit

Motor -

Gas Solenoid +

Gas Solenoid -

Tach COM

2

1

3

4

J82

2

1

6

3

4

5

J83

1

3

4

J81

2

1

3

4

2

1

6

3

4

5

J85

8

7

10

9

11

12

2

1

6

3 4 5

8

7

10

9

FEED HEAD CONTROL

P.C. BOARD

563

561

POS

SPI
CKTS

V

)

H

C

n

i

V

-

+

Y

L

P

P

U

S

R

E

W

O

P

n

i

V

+

3

-

2

8

J

3

-

1

8

J

6

-

3

8

J

5

-

3

8

J

4

-

2

8

J

4

-

1

8

J

6

5

8

7

576

562

577

575

Tach Signal

14

13

16

15

R

O

T

I

N

O

M

E

G

A

T

L

O

V

R

O

T

O

M

5

J88

Y

L

P

P

U

S

k

4

1

J86

Y

L

P

P

U

S

R

E

W

O

P

see power
supply section
molex

5
6

6

J83

2

+15V

-15V

-5V

+5V(TA

+5

COM

+ motor

1200uF

COM

+ MOTOR

Vin

INPUT VOLTAGE MONITOR
(MOTOR FETS ARE BOTH
OFF WHEN INPUT VOLTAGE
DROPS BELOW 20V)

V

5

+

+

COM

+5V (TACH)

TACH INPUT

COM

DRIVE

BRAKE

+ MOTOR

PWM

MOTOR

CONTROL

PULSE BY PULSE
PEAK CURRENT
LIMIT (27 AMPS)

AVERAGE
CURRENT
LIMITING

+15V

gas
solenoid
PWM control
ckts

CPLD

M

O

C

k

2

k

5

7

.

4

COM

INTERNAL
SWITCH
INPUTS

A=1

+5V

A=1

WFS
ANALOG
INPUT

V

5

1

+

S

T

U

P

N

I

H

C

T

I

W

S

L

A

N

R

E

T

X

E

k

5

7

.

4

0

0

5

k

5

7

.

4

0

0

5

0

0

5

k

5

7

.

4

OM

4.75k

2k

COM

C

k

2

k

5

7

.

4

+15V

J84

78k

78k

40

+

-

1M

1M

PWM
CONTROL
FOR
CONTACTOR

ARC VOLTAGE
FEEDBACK
IN PUT

Schematic G3883

559

Gas Purge
15 VDC when Purge OFF
0 VDC when Purge ON

For programming at LECo factory only.
Not field reprogrammable.

J87

15

16

13

12

11

14

9 10

7

8

5

4

3

6

1 2

COM

NEG

501

502

COM

Motor +

J84

FEEDPLATE

Located on the right
side of the control box.

Schematic M19752

TOROID

TOROID

TOROID

TOROID

TOROID

GND-C

567A

5

J83

n

i

V

+

J88

4.5 A PEAK
CURRENT
LIMIT

The contactor is
located behind
the glastic panel
next to the motor.

MICRO
CONTROLLER

Wo

rk

Located under the cover
in the control box ably.

Located behind the wire drive

Not a PC board; no schematic.

Access this connector
by removing the wire
drive asbly.

Located on the case
front. Remove the wire
drive asbly to gain
access.

Display
Board
Circuit

N.C.

Located on the lower left
of the front of the case.

N.A. CAVITY NUMBERING SEQUENCE AS VIEWED FROM COMPONENT SIDE OF BOARD.
N.B. CAVITY NUMBERING SEQUENCE AS VIEWED FROM LEAD SIDE OF CONNECTOR.
N.C. TOGGLE SWITCHES AND POTENTIOMETERS SHOWN FROM CONNECTION SIDE OF SWITCH.

+ 5

V

CO

M

+ 1

5V

Located behind the insulating
wire drive panel. Remove the
wire drive ably to gain access.

Located under the cover at
the rear of the feeder

All LED’s light
briefly

Show CC/CV
mode and HI/LO
gear

Idle:
Display WFS, “---”
Wire Drive: OFF
Gas Solenoid: OFF

Enter Press and
Spin Mode

G

AS PU

R

G

E

SW

ITC

H

D

EPR

ES

SED

G

AS PU

R

G

E

SW

IT

CH OF

F

15-110 VDC from
welding power
source

526C

526B

ON/OFF

SWITCH

526

526B

587 589

587

589

2-STEP

TRIGGER

INTERLOCK

S2

554A

2 S

tep

2 S

tep

2 Step Trigger
15 VDC for 2 Step
0 VDC for Interlock

Interlock
Circuit

83% Procedure Input
0 VDC Normal
9 VDC 83% switch Closed
and Trigger Open

Trigger
15 VDC when Trigger and 83%
Switch Open
9 VDC when Trigger Open, 83%
Switch Closed
0 VDC when Trigger Closed

G-3

NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual.

Advertising