Service and repair should be performed by only Lincoln Electric factory trained
personnel. Unauthorized repairs performed on this equipment may result in danger
to the technician or machine operator and will invalidate your factory warranty. For
your safety and to avoid electrical shock, please observe all safety notes and pre-
cautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to per-
form the test / repairs safely, contact the Lincoln Electric Service Department for
electrical troubleshooting assistance before you proceed. Call 1-888-935-3877.

LN-15

F-11

F-11

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

WARNING

TROUBLESHOOTING & REPAIR

BOOST POWER BOARD TEST

TEST DESCRIPTION

This procedure will determine if the correct input voltage is being applied to the Boost
Power Board and if the correct output voltage is being produced by the Boost Power
Board.

MATERIALS NEEDED

Volt/Ohm Meter

DC Voltage Source (15 to 110 VDC)