PROTECTION BOARD OUTPUT TEST(cont.)

TEST PROCEDURE

12. Open S4 and Turn Power OFF

13. Move probes to test between leads 306 (+) and

275 (-). (See Figure F.6)

14. Turn Power ON and close S4. If voltage is less

than 1 VDC, Protection Board is OK. If voltage is
greater than 14 VDC, Protection Board may be
defective.See Overvoltage Protection DC
Trigger Circuit
test, Step

11.

PROTECTION

L7915

306

313

275F

311

J8

J15

FIGURE F.6 - INSERTING PROBES