Troubleshooting & repair, Output diode replacement procedure (cont.) – Lincoln Electric INVERTEC SVM101-B User Manual

Page 91

Advertising
background image

V300-I

TROUBLESHOOTING & REPAIR

PROCEDURE (Diode Modules)

1. Turn main power OFF.

2. Perform

Input Filter Capacitor Discharge

proce-

dure detailed in Maintenance section..

3. Detach and remove both Switch Board assemblies

and attached capacitors. See

Switch Board

Removal and Replacement

procedure

4. Detach the fan shroud to gain access to the diode

heat sink and mounting bracket. When the fan
shroud is lifted, the tabs securing the heat sink
mounting bracket will release.

5. Move the diode heat sink and mounting bracket

away from the Case Back.

6. Disconnect the leads from the defective Module and

remove the module from the heat sink.

7. Mount the new module and re-connect the leads.

IMPORTANT: The replacement module will come
with an instruction sheet that addresses surface
preparation, torque values and hardware changes.
Failure to follow these instructions may result in
subsequent breakdown.

8. Reassemble the unit being careful to use all of the.

insulating materials. Also make certain to replace
all disconnected leads in their proper location.
Failure to do so may result in machine damage
when the power is applied.

9. Perform the

Test After Switch Board or Capacitor

Replacement.

F-61

F-61

Re

tu

rn

t

o Se

ct

io

n T

O

C

Re

tu

rn t

o Se

ct

io

n T

O

C

Re

tu

rn t

o Se

ct

io

n T

O

C

Re

tu

rn t

o Se

ct

io

n T

O

C

Re

tu

rn t

o Ma

st

e

r T

O

C

Re

tu

rn t

o Ma

st

e

r T

O

C

Re

tu

rn t

o Ma

st

e

r T

O

C

Re

tu

rn t

o Ma

st

e

r T

O

C

OUTPUT DIODE REPLACEMENT PROCEDURE (cont.)

FIGURE F.32 - RECTIFIER ASSEMBLY WITH DIODE MODULES

Advertising