B300-I

TROUBLESHOOTING & REPAIR

TEST PROCEDURE

1. Turn main power OFF.

2. Perform Input Filter Capacitor Dis-charge proce-

dure detailed in Mainten-ance section..

3. Connect a shorting conductor across terminals 14

and 53 of Protection Board.

4. Set an ohmmeter to X1000 range and place probes

on terminals 9 (+) and 12 (-) of one Switch Board.
The meter will show the Capacitors charging up
and may take a minute or so to stabilize. The final
meter reading should not exceed 8600 ohms (8.6
on the scale).

5. Test the other Switch Board the same way.

NOTE: Repeat the Input Filter Capacitor Dis-charge
procedure.

6.

Remove the shorting conductor set up in step 3.

7.

Install 5-amp fuses in the input supply fuse holders.

NOTE: These fuses should be installed to protect
against excessive current flow caused by a short
circuit during the procedure.

8.

Turn on the machine.

9.

With the output free of a load, check the open cir-
cuit voltages of the output.

10. Connect the machine for 440- or 575-volt opera-

tion.

11. With the output free of a load, check open circuit

voltages of the output. Voltage should be 70 VDC.

12. Remove the 5-amp fuse from the input supply fuse

holders.

13. Install 20-amp fuses and test under load.

NOTE: A resistive-type grid load bank is recom-
mended.

14. Perform Retest After Repair.

F-58

F-58

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

TEST AFTER SWITCH BOARD OR CAPACITOR REPLACEMENT (cont.)

FIGURE F.30 - PLACEMENT OF SHORTING JUMPER

Advertising