Troubleshooting & repair, Input rectifier test – Lincoln Electric INVERTEC SVM101-B User Manual

Page 64

Advertising
background image

V300-I

TROUBLESHOOTING & REPAIR

TEST PROCEDURE

1. Perform

Input Filter Capacitor Discharge

Procedure as detailed in this section.

2. Locate Input Rectifier (Component D-13).

3. Locate leads needed to perform tests shown in

Figure F.11.

4. Use ohmmeter to perform tests shown in Table F.5.

Replace the Inpit Rectiferif readings are not as indi-
cated

NOTE: When installing a new Input Rectifier, torque
mounting nuts (in a cross tightening pattern) to 6
inch-pounds (.7 Nm). Torque terminals to 26 inch-
pounds (3 Nm). ALWAYS GO TO STEP 6 TO
CHECK RELATED COMPONENTS.

6. Inspect Main Power Switch S1 and replace if faulty.

Go to step 7.

7. Test Capacitors C1 and C2 and replace both

Capacitors if either is faulty.

NOTE: Faulty Capacitors could be the reason for a
defective Input Rectifier.

Visually inspect Capacitors for leakage, damage, etc.,
and use appropriate test equipment to determine com-
ponent integrity (also check/test Switch Boards for
damage).

F-34

F-34

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

INPUT RECTIFIER TEST

Test Points

Steps

+ Probe

– Probe

Acceptable Meter Reading

A

9

H1

Greater than 1K ohms

B

9

A

Greater than 1K ohms

C

9

H5

Greater than 1K ohms

D

H1

9

Less than 100 ohms

E

A

9

Less than 100 ohms

F

H5

9

Less than 100 ohms

G

12

H1

Less than 100 ohms

H

12

A

Less than 100 ohms

I

12

H5

Less than 100 ohms

J

H1

12

Greater than 1K ohms

K

A

12

Greater than 1K ohms

L

H5

12

Greater than 1K ohms

TABLE F.5

FIGURE F.11 - INPUT RECTIFIER LOCATION

Advertising