Troubleshooting & repair, V300-i – Lincoln Electric INVERTEC SVM101-B User Manual

Page 67

Advertising
background image

V300-I

TROUBLESHOOTING & REPAIR

6. Turn main power OFF.

7. Perform

Input Filter Capacitor Discharge

Procedure detailed in this section.

Test resistance of the Black and White leads from
1J3 and 2J3 to the shunt. See Figure F.14.

a.

If zero ohms resistance (continuity) is shown,
test is OK.

b.

If resistance of any value is shown, check wire
and connections.

NOTE: On earlier codes the terminals on the shunt
leads were crimped but not soldered. Corrosion may
cause inaccurate current readings. Cleaning and sol-
dering the terminals to the leads may eliminate that
problem.

If tests for steps 5, 7, are OK and the machine contin-
ues to experience the problem, the Control Board
should be replaced.

F-37

F-37

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

OVERCURRENT PROTECTION CURRENT TRIGGER TEST (cont.)

FIGURE F.14 - CONTROL BOARD TEST POINTS

G2527

CONTROL

1J3 (Black)

2J3 (White)

J5

J1

J2

J4

J3

FIGURE F.15 - OVERCURRENT PROTECTION CURRENT TRIGGER CIRCUIT.

BLACK

CHOKE

WHITE

(-) OUTPUT
TERMINAL

6J1

302

275D

1J3

L3

1J1

2J3

CONTROL

BOARD

400 AMP

SHUNT

Advertising