TROUBLESHOOTING & REPAIR

TEST PROCEDURE

1. Locate the Output Terminals on front panel.

2. Remove any cables from Output Terminals.

3. Test for more than 200 ohms resistance between

positive and negative Output Terminals: positive
meter lead to the positive terminal, negative meter
lead to the negative terminal.

NOTE: Polarity of test leads is important.

a.

If reading is more than 200 ohms, Output
Diodes are OK.

b.

If reading is less than 100 ohms, one or more
Output Diode is shorted. Test all Output Diodes
(D-1 thru D-12) or diode modules individually.

NOTE: On codes prior to 10200 the diodes should
also be tested individually to check for “Open”
diodes. An open diode may cause an imbalance
condition when output is activated. Be sure to per-
form the Input Filter Capicitor Discharge
Procedure
as detailed in this section.

F-32

F-32

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

OUTPUT DIODE TEST (cont.)

-

+

- PROBE

+ PROBE

LINCOLN

FIGURE F.10 — TESTING OUTPUT DIODES.