TROUBLESHOOTING & REPAIR

F-4

F-4

IDEALARC CV-400

Observe Safety Guidelines

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
216-383-2531 or 1-800-833-9353.

PROBLEMS
(SYMPTOMS)

POSSIBLE AREAS OF
MISADJUSTMENT(S)

RECOMMENDED
COURSE OF ACTION

OUTPUT PROBLEMS

Major physical or electrical damage
is evident when the sheet metal
cover(s) are removed.

Machine is dead - no output - no
fan - no pilot light.

The machine is dead - no output -
no fan - the pilot light is on.

1. Contact your local authorized

Lincoln Electric Field Service
Facility for technical assistance.

1. Make sure the input power

switch is ON.

2. Check the three-phase input

voltage at the machine.

Input

voltage must match the rating
plate and the reconnect panel.

3. Check for blown or missing

fuses in the input lines.

1. Check the three-phase input

voltage at the machine.

Input

voltage must match the rating
plate and the reconnect panel.

2. Check for blown or missing

fuses in the input lines.

1. Contact the Lincoln Electric

Service Department, (216) 383-
2531 or 1-800-833-9353 (WELD).

1. Check the input power switch

(S1) for proper operation. See
the Wiring Diagram.

2. Check the leads associated with

the power switch (S1) and the
control transformer (T2) for
loose or faulty connections. See
the Wiring Diagram.

3. Perform the

Control

Transformer Test.

1. Perform the

Input Contactor

Test.

2. Check the associated leads for

loose or faulty connections
between the input contactor
(CR1), the reconnect panel and
the main transformer. See the
Wiring Diagram.

3. Perform the

Main Transformer

Test.