TROUBLESHOOTING & REPAIR

F-53

F-53

IDEALARC CV-400

RETEST AFTER REPAIR

Retest a machine:

• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the

machine’s electrical characteristics. OR

• If you repair or replace any electrical components.

INPUT IDLE AMPS AND WATTS

Input Volts/Phase/Hertz

Maximum Idle Amps

Maximum Idle KW

200/3/60

10.9

1.2

208/3/60

10.5

1.2

220/3/60

9.9

1.2

230/3/60

9.5

1.2

380/3/60

5.8

1.2

400/3/60

5.5

1.2

415/3/60

5.3

1.2

440/3/60

5.0

1.2

460/3/60

4.8

1.2

500/3/60

4.4

1.2

575/3/60

3.8

1.2

200/3/50

19.8

1.2

220/3/50

18.0

1.2

230/3/50

17.2

1.2

380/3/50

10.4

1.2

400/3/50

9.9

1.2

415/3/50

9.5

1.2

440/3/50

9.0

1.2

500/3/50

7.9

1.2

OPEN CIRCUIT VOLTAGES

Test Points

Input Hertz

Open Circuit Volts

Welding Output Terminals

60

43/47VDC

Welding Ouput Terminals

50

43/47VDC

Auxiliary Output (#31 - #32)

60

114/124VAC

Auxiliary Output (#31 - #32)

50

109/119VAC

Auxiliary Output (#41 - #42)

60

43.8/47.5VAC

Auxiliary Output (#41 - #42)

50

42.0/45.6VAC

Auxiliary Output (#51 - #52)

50

220/231VAC

WELDING OUTPUT LOAD TEST

Output Control Setting

Amps

Volts

Minimum

75 to 150

6 to 11

Maximum

525

more than 41.2