TROUBLESHOOTING & REPAIR

F-8

F-8

IDEALARC CV-400

Observe Safety Guidelines

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
216-383-2531 or 1-800-833-9353.

PROBLEMS
(SYMPTOMS)

POSSIBLE AREAS OF
MISADJUSTMENT(S)

RECOMMENDED
COURSE OF ACTION

OUTPUT PROBLEMS

The output terminals are always
electrically “hot.”

1. Remove any external leads that

may be connected to the 14 pin
amphenol or the terminal strip.
If the problem disappears, the
fault is in the control cable or
wire feeder.

1. Check for an internal short

between leads #2 and #4. See
the Wiring Diagram.

2. Remove plug J3 (SCR gate

leads) from the control board. If
the problem disappears, the
control board may be faulty.
Replace. If the output terminals
are still electrically “hot,” perform
the

SCR/Diode Rectifier

Bridge Test.

3. The snubber board may be

faulty. Check or replace.