TROUBLESHOOTING & REPAIR

F-25

F-25

IDEALARC CV-400

ACTIVE SCR TEST (continued)

TEST PROCEDURE

1. Disconnect the main input supply power to

the machine.

2. With the 5/16” nut driver, remove the case

top and sides. Remove the screws holding
the front panel and lower the panel.

3. Disconnect the welding cables from the

welding output terminals.

4. Locate and remove molex plug P3 from the

control board. See Figure F.12.

5. Locate and remove molex plug P5 from the

snubber board. See Figure F.13.

6. Locate and remove lead #204 from resistor

R2 (7.5 ohms, 100 Watts). See Figure F.14.

7. Using 9/16” wrench, remove the positive

capacitor strap lead and small lead terminal
from the positive rectifier plate and output
shunt junction. See Figure F.10.

FIGURE F.12 – CONTROL BOARD PLUG

P1 AND P3 LOCATIONS

FIGURE F.13 – SNUBBER BOARD

PLUG P5 LOCATION

FIGURE F.14 – RESISTOR R2 LOCATION