Troubleshooting & repair, Normal open circuit voltage waveform – Lincoln Electric IDEALARC SVM136-A User Manual
Page 68
Advertising
TROUBLESHOOTING & REPAIR
F-28
F-28
IDEALARC CV-400
This is the typical DC open circuit
voltage waveform generated from a
properly operating machine. Note
that each vertical division represents
20 volts and that each horizontal divi-
sion represents 2 milliseconds in
time.
Note: Scope probes connected at
machine output terminals: (+) probe
to positive terminal, (-) probe to neg-
ative terminal.
SCOPE SETTINGS
Volts/Div.....................20V/Div.
Horizontal Sweep.....2 ms/Div.
Coupling ............................DC
Trigger .........................Internal
NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM
MAXIMUM OUTPUT SETTING – NO LOAD
CH1
0 volts
2 ms
20 volts