INSTALLATION

CV-250

A-3

FIELD INSTALLED OPTIONS

For installation of compatible field installed options
(see the ACCESSORIES section of this manual and
refer to the instructions included with those options.

REQUIRED EQUIPMENT-CONTROL
CABLE CONNECTIONS

Follow the instructions below which are appropriate
for the wire feeder that will be used.

LN-7 to CV-250

a) Turn the CV-250 Power switch to the "OFF" posi-

tion.

b) Connect the LN-7 control cable to the wire feeder

receptacle on the CV-250.

c) See OUTPUT CONNECTIONS for connection of

work and electrode cables.

LN-25 to CV-250

a) Turn the CV-250 Power switch to the "OFF" posi-

tion.

b) Plug a K484 jumper plug into the CV-250 wire

feeder receptacle.

c) See OUTPUT CONNECTIONS for connection of

work and electrode cables.

The output terminals are energized at all times when
the K484 is plugged in.

------------------------------------------------------------------------

LN-742 to CV-250

a) Turn the CV-250 Power switch to the "OFF" posi-

tion.

b) Connect the LN-742 control cable to the wire

feeder receptacle on the CV-250.

c) See OUTPUT CONNECTIONS for connection of

work and electrode cables.

Connection of Remote Control (K857)

NOTE: The K864 Remote Control Adapter is required

to install the K857.

Plug the K864 Remote Control Adapter into the power
source's 14-pin receptacle. Plug the K857 Remote
Control into the 6-pin receptacle of the K864 adapter.
If possible, tape the Remote cable to the heavy output
leads, so they can protect the smaller Remote cable
from damage and abuse.

OUTPUT CONNECTIONS

Output cables must have Magnum Twist-Mate™ plugs
for connection to the CV-250. Order K852-70 for con-
necting 1/0-2/0 (50-70 mm

2

) cables. Refer to S18737

for instructions on installing these plugs.

Use the shortest possible cable lengths. See Table
A.1 for recommended cable sizes based on length.

Connect the positive output lead to the terminal
marked "+". The negative output lead can be hooked
to either the low inductance terminal (marked "

") or the high inductance terminal (marked

" ").

WARNING

TABLE A.1

Cable Sizes for Combined Lengths of Copper

Electrode and Work Cable

Machine Size

Lengths up to

150 ft

150 to 200 ft

250 A 100%

(300 A 60%)

1/0 (50mm2)

2/0 (95mm2)