Diagrams, Twist-mate cable plug installation instructions, Cv-250 – Lincoln Electric IDEALARC CV-250 User Manual

Page 36

Advertising
background image

F-9

DIAGRAMS

F-9

CV-250

TWIST-MATE CABLE PLUG INSTALLATION INSTRUCTIONS

TURN THE POWER SWITCH OF THE WELDING POWER

SOURCE "OFF" BEFORE INSTALLING PLUGS ON CABLES

OR WHEN CONNECTING OR DISCONNECTING PLUGS TO

WELDING POWER SOURCE.

1.

WELDING CABLE

BOOT

TRIM

Slide the copper tube into the brass plug.

Insert cable into copper tube.

COPPER TUBE

Slide rubber boot over brass plug. The rubber boot must be

positioned to completely cover all electrical surfaces after

the plug is locked into the receptacle.

SET SCREW

BRASS PLUG

BOOT MARKING

2

2

50-70

70-95

CABLE SIZE

1/0-2/0

CABLE SKIN LENGTH

1 INCH (25.4mm)

2.

2/0-3/0

50-70

70-95

mm )

mm )

(

(

AMERICAN (EUROPEAN) RANGE

CHECK THAT THE CONNECTOR BOOT IS MARKED FOR THE

APPROPRIATE CABLE SIZE PER TABLE BELOW; AND

SKIN CABLE JACKET TO LENGTH SPECIFIED:

1 INCH (25.4mm)

35-50

2

mm )

(35-50

#2-#1

TWIST-MATE WELDING CABLE PLUG INSTALLATION INSTRUCTIONS

9-20-91J

1.5 INCH (38.1mm)

must apply firm pressure against welding cable. The top of the

(70-95 size may

have 2 set

screws)

SEE

ABOVE

Tighten set screw(s) to collapse copper tube. Screw(s)

brass plug after tightening.

set screw(s) will be nearly flush or below the surface of the

7.

6.

5.

4.

3.

Slide rubber boot onto cable end.

If necessary, trim cable end of boot at groove(s) to match cable

diameter. Boot must fit tightly enough to seal around outside

different cable diameters without trimming. These boots do not

based lubricant will help to slide the boot over the cable.

have grooves at the cable end. Soap or other non petroleum

diameter of cable. NOTE: Some boots are designed to accommodate

S18737

Advertising