Installation, Technical specifications – idealarc cv-250 – Lincoln Electric IDEALARC CV-250 User Manual

Page 8

Advertising
background image

A-1

CV-250

A-1

INSTALLATION

TECHNICAL SPECIFICATIONS – IDEALARC CV-250

Code

Number

10013

10014

Volts at Rated Amperes

30

32
30

Auxiliary Power

42 Volts AC, 10 Amps

115 Volts AC, 5 Amps

( Both Circuit Breaker Protected)

Idle Current - Amps

11/10/5

Input Current at

Rated Output

100% Duty Cycle 56/51/26

60% Duty Cycle 62/56/28

100% Duty Cycle 51/26/20

60% Duty Cycle 56/28/22

Amps

250

300
250

Normal Open Circuit Voltage

10-43

MAX OCV: 50

Input kVA

60% Load - 22.3

100% Load - 20.3

Power Factor at 100% Load

.53

Standard

Voltage

208/230/460/3/60

230/460/575/3/60

Duty Cycle

100% Duty Cycle

NEMA Class I (100)

60% Duty Cycle

100% Duty Cycle

Welding Current/Voltage Range

(Continuous)

30A/7V - 300A/32V

DC

Efficiency at 100% Load

72%

Idle Power

800W

INPUT - THREE PHASE ONLY

RATED OUTPUT

OUTPUT

MISC. INFORMATION

Height

Width

Depth

Weight

21.5 in.

19.5 in.

27.0 in.

(Lift bail, add 3.12 in)

300 lbs
(137 kg)

546 mm

495 mm

686 mm

(Lift bail, add 80 mm)

PHYSICAL DIMENSIONS

Advertising