Diagrams, Cv-250 – Lincoln Electric IDEALARC CV-250 User Manual

Page 33

Advertising
background image

F-6

DIAGRAMS

F-6

CV-250

CV POWER SOURCE TO AN LN-25 / K444-1

Only qualified persons should install, use or

service this machine.

using the disconnect switch at the fuse box

WARNING

Turn off input power to the Welding Power Source

Before connecting the wire feeder.

ELECTRIC

SHOCK

CAN KILL

N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.

N.B. DIAGRAM SHOWS ELECTRODE POSITIVE. TO CHANGE POLARITY, TURN POWER "OFF",

ELECTRODE CABLE

-

+

14 PIN

AMPHENOL

POWER SOURCE

CV/CV-I

TO WORK

LN-25

WIRE FEEDER

OPTIONAL

K484 JUMPER

PLUG

OPTIONAL K864 REMOTE

CONTROL ADAPTER

WITH K444-1 OPTION

N.D.N.D.

N.C.

N.C. CONNECT THE K484 JUMPER PLUG TO THE 14 PIN RECEPTACLE OF THE

K864 REMOTE CONTROL ADAPTER. CONNECT THE 6 PIN PLUG FROM THE

LN-25 (WITH K444-1 OPTION) TO THE 6 PIN RECEPTACLE OF THE K864

N.D. THE POWER SOURCE TERMINALS ARE ALWAYS "HOT" WHEN THE K484 JUMPER

PLUG KIT IS INSTALLED.

REVERSE ELECTRODE AND WORK CABLES AT POWER SOURCE, SWITCH LN-25 POLARITY SWITCH.

REMOTE CONTROL ADAPTER. SWITCH THE POWER SOURCE "LOCAL/REMOTE" SWITCH TO REMOTE.

CLEVELAND, OHIO U.S.A.

S20663

CV/CV-I POWER SOURCE TO LN-25 WITH K444-1 OPTION CONNECTION DIAGRAM