MAINTENANCE

D-1

SAFETY PRECAUTIONS

GENERAL MAINTENANCE

1. The fan motor has sealed bearings which require

no service.

2. In extremely dusty locations, dirt may clog the air

channels causing the welder to run hot with prema-
ture tripping of thermal protection. Blow out the
welder with low pressure air at regular intervals to
eliminate excessive dirt and dust build-up on inter-
nal parts.

MACHINE AND CIRCUIT PROTECTION

The CV-250 Control PC Board has built-in diagnostic
routines to alert the operator when trouble exists.
When a trouble condition occurs, the CV-250 meter
will display an error code, in the form "EXX", where
"XX" refers to a specific error. See TROU -
BLESHOOTING section for an explanation of the error
codes.

The power source is thermostatically protected
against overload or insufficient cooling. If the machine
is overloaded, the thermostat will open, thermal pro-
tection indicator light will turn on, and the output will
be zero. The fan will continue to run and auxiliary
power will still be available. The thermostat will
remain open until the machine cools, at which time it
will close and the output will again be available.

The CV-250 is electronically protected against over-
loads and accidental short circuits. The overload pro-
tection circuit automatically reduces the output current
to a safe value when an overload is detected. If the
circuitry senses a short circuit, it will shut off the CV-
250 output. The short circuit protection circuit can be
reset by turning the CV-250 Power switch OFF for at
least 10 seconds. Remove the short before turning
the Power switch ON again.