Diagrams, Cv power source to a k867 universal adapter – Lincoln Electric IDEALARC CV-250 User Manual

Page 30

Advertising
background image

F-3

DIAGRAMS

F-3

CV-250

CV POWER SOURCE TO A K867 UNIVERSAL ADAPTER

N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.

N.C. INSULATE EACH UNUSED LEAD INDIVIDUALLY.

N.C.

76

82

81

SPARE

2

4

41

42

31

32

GND

21

77

75

REMOTE OUTPUT CONTROL

N.D.

2

4

10K

MIN.

Only qualified persons should install, use or

service this machine.

using the disconnect switch at the fuse box

WARNING

Turn off input power to the Welding Power Source

Before connecting the wire feeder.

ELECTRIC

SHOCK

CAN KILL

6-18-93

NOT USED ON CV/CV-I POWER SOURCES

42 VAC

115 VAC

N.E.

POWER SOURCE FRAME CONNECTION

WIRE FEEDER VOLTMETER CONNECTION

CONNECTS TO (WORK TERMINAL) OF POWER SOURCE

CONNECT TOGETHER FOR

WELDING OUTPUT

N.F.

N.B. DIAGRAM SHOWS ELECTRODE POSITIVE. TO CHANGE POLARITY, TURN POWER "OFF",

N.D. FOR WIRE FEEDERS THAT RETURN A SIGNAL FOR WELDING OUTPUT, USE ISOLATION

RELAY TO CLOSE LEADS 2 & 4.

TO

K867

N.E. REFER TO POWER SOURCE INSTRUCTION MANUAL FOR MAXIMUM AUXILIARY

CURRENT DRAW.

TO

WIRE

FEEDER

K867 UNIVERSAL

ADAPTER PLUG

-

+

14 PIN

AMPHENOL

POWER SOURCE

CV/CV-I

TO WORK

ELECTRODE CABLE

{

REVERSE ELECTRODE AND WORK CABLES AT POWER SOURCE.

N.F. NOT PRESENT ON ALL MACHINES

N.F.

S20658