13

Master Reset

CAUTION: Performing a master reset will clear

the entire memory of the AKR-1 and return all
programmable options to the factory default values.
ALL ENTRY CODES AND TRANSMITTERS WILL BE
ERASED.

STEP 1

Disconnect power from the keypad.

STEP 2

Press and hold down the * and # keys.

STEP 3

Apply power to the keypad, continue holding the keys
down until the red indicator starts fl ashing.

STEP 4

Release the keys. The red and yellow indicators will
remain lit until the process is complete, then the yellow
indicator will go out.

Resetting the Master Code

STEP 1

Open the AKR-1 case.

STEP 2

Locate jumper JP2. This jumper is used to reset the
master code.

STEP 3

With power applied to the keypad, remove jumper JP2.
The keypad will begin to beep, signaling that the code
has been reset.

STEP 4

Replace jumper JP2. THE MASTER PROGRAMMING
CODE IS NOW 123456.

Solid State Outputs

The two solid state outputs (Output #3 & Output #4) can be
programmed to activate during various conditions. These outputs
can be used to activate indicators or sounders. See Figure 8 for
wiring examples using the solid state outputs.

OUTPUT #3

OUTPUT #4

COMMON

GROUND

AKR-1
POWER

1K

9

LED

1K

9

LED

ELECTRONIC
BEEPER

EXAMPLE 1: OUTPUT #3 LIGHTS AN LED,

OUTPUT #4 LIGHTS AN LED AND SOUNDS A BEEPER

EXAMPLE 2: OUTPUT #3 LIGHTS A LAMP POWERED FROM AN EXTERNAL

SOURCE, OUTPUT #4 TRIGGERS A NORMALLY OPEN ALARM PANEL ZONE

OUTPUT #3

OUTPUT #4

EACH

OUTPUT

100 mA

MAXIMUM

ALARM PANEL

N.O. ZONE

COMMON

END-OF-LINE
RESISTOR

POWER

SOURCE

LOW VOLTAGE

LAMP

EACH

OUTPUT

100 mA

MAXIMUM

6

4

5

4

5

8

Figure 8. Using Solid State Outputs