WIRING DIAGRAM

1

2

3

4

5

6

7

8

9

DC OR AC POWER

INHIBIT

COMMON

REQUEST-TO-ENTER

EARTH GROUND

N.O.

COMMON

N.C.

OUTPUT #3

OUTPUT #4

N.O.

COMMON

N.C.

COMMON

10

11

12

13

14

15

AKR-1 TERMINALS

MAIN

RELAY

AUXILIARY

RELAY

1

2

3

4

5

6

7

8

9

DC OR AC POWER

DOOR SENSE

COMMON

REQUEST-TO-ENTER

EARTH GROUND

N.O.

COMMON

N.C.

OUTPUT #3

OUTPUT #4

N.O.

COMMON

N.C.

COMMON

10

11

12

13

14

15

MAIN

RELAY

AUXILIARY

RELAY

AKR-1 TERMINALS

GATE

OPERATOR

INHIBIT

TIMER

OPEN

FIRE

ACCESS

ELECTRIC

DOOR

STRIKE

DOOR

SWITCH

ALARM

CONTACT

OPTIONAL WIRING

REQUIRED WIRING

TO ALARM

SYSTEM

TRANSFORMER
ISOLATED
AUXILIARY
POWER

CAUTION

IF THE UNIT IS AC POWERED,

AND ONE SIDE OF THE POWER TRANSFORMER SECONDARY

IS CONNECTED TO EARTH GROUND, CONNECT THE GROUNDED

SIDE TO THE "-" POWER TERMINAL OF THE UNIT.

POWER
SUPPLY

OPTIONAL WIRING

REQUIRED WIRING

OTHER WIRING

GROUND

STAKE

GROUND

STAKE

NOTES:
1. ALARM SHUNT SET FOR AUXILIARY RELAY
2. TERMINAL 14 SET FOR DOOR SENSE

NOTE:
TERMINAL 14 SET FOR INHIBIT

TYPICAL DOOR INSTALLATION WIRING

TYPICAL GATE INSTALLATION WIRING

217350 D IMAGE 5