INSTALLATION

POWER FEED 10 DUAL

A-8

MSB - Most Significant Bit or Byte. This is the bit in a binary number or DIP switch bank that is furthest to the left.
LSB - Least Significant Bit or Byte. This is the bit in a binary number or DIP switch bank that is furthest to the right.

S2 DIP Switch Bank on Control Box Motherboard (For software version S24456)

Switch

Off

On

1

Network Group ID, MSB (Assigns Control Box to a specific group) (Off is factory setting)

2

Network Group ID, LSB (Assigns Control Box to a specific group ) (Off is factory setting)

3

4-Step Domestic Configuration

4-Step European Configuration

4

Power Feed 10 Dual / Dual

Power Feed 11

5

Procedure Change with Trigger “OFF”

Procedure Change with Trigger “ON”

6

Set lower limits

7

Set upper limits

8

Must be on for all units (Permits selection of extended modes)

Note: the factory shipped settings for the S2 switches are as follows:
PF-10 (and Dual) Domestic - switches 1-7 “OFF”, 8 “ON”

PF-10 (and Dual) European - switches 1,2,4-7 “OFF”, 3,8 “ON”

PF-11 Domestic - switches 1-3,5-7 “OFF”, 4,8 “ON”

PF-11 European - switches 1,2,5-7 “OFF”, 3,4,8 “ON”

DIP SWITCH 6

DIP SWITCH 7

DIP SWITCH 8

Acceleration 1 (slow)

Off

Off

On

Acceleration 2

Off

On

Off

Acceleration 3

Off

On

On

Acceleration 4

On

Off

Off

Acceleration 5 (fast ) (factory setting)

Off

Off

Off

Setting Wire Drive Acceleration Rate Using

(All software versions)

DIP Switch S1 on the Control Box Motherboard