background image

C-9

ACCESSORIES

C-9

LINC NET RECEPTACLE (INPUT)

Power Feed Wire Feeder Optional Input Connector
Installation into the Control Box Cabinet and
Conversion to Fixture Wire Feeder

1. Turn off power.

2. Remove the screws from the front of the lower

and middle option panels of the Control Box cabi-
net.

3. Tilt the option panels away from the front opening

of the Control Box cabinet. If the option panel has
an electrical connector, disconnect it from the
main printed circuit board (note connection point
for re-connection later). Remove the option panel
and set aside.

4. Disconnect the connector located at the back wall

of the Control Box cabinet.

5. Loosen (do not remove) the four screws located

on the back wall of the Control Box cabinet.

6. Lift Control Box cabinet off of the four screws

loosened above and set on a work surface. Re-
tighten the four screws to secure for future use.

7. Remove the plastic plug (black) from the right hole

in the bottom wall of the Control Box cabinet and
insert it into the hole in the front of the Feeder Head.

8. Place the Optional Input Connector (Amphenol)

through the hole opened by the previous step
(place from the inside, out). Rotate the Optional
Input Connector so itʼs aligning key is positioned
to the front of the Control Box cabinet. Fasten the
Optional Input Connector to the bottom wall of the
Control Box cabinet with the four screws provided
and connect the optionʼs opposite end to the con-
nector referred to in step 4.

9. Secure the choke (large circular component of the

Optional Input Connector) by inserting itʼs leads
into the white nylon clip located near the Optional
Input Connector on the back wall of the Control
Box cabinet. Insert the choke leads only.

10. Install an Optional Output Connector (Lincoln

stock # K1549-1) into the Control Box cabinet, if
not already present.

11. Mount the Control Box cabinet to the work station fix-

ture at this time, if desired. The four holes in the back
wall of the Control Box cabinet can be used for this

purpose.

12. Re-install the lower and middle option panels by

reversing the removal process. While re-installing
the option panels, ensure clearance between
Optional Input Connector components, Control
Box wiring harness, and option panel wiring har-
ness (if any).

K162-1 - WIRE SPINDLE ADAPTER

Spindle for boom mounting Readi-Reels and 2” (51
mm) I.D. spools with up to 60 lb. (27.2 kg) capacity.
User mounted to appropriately prepared boom frame-
work. Includes an easily adjustable friction brake for
control of overrun (a 2” spindle is standard on Power
Feed 10 Dual Bench model).

When a 2” (51 mm) spindle is used with Readi-Reels,
or coils not on 12” (305 mm) or 8” (203 mm) O.D.
spools, an adapter is required:

K1504-1 - COIL ADAPTER

Permits 50 lb to 60 lb (22.7-27.2 Kg.) coils to be
mounted on 2” (51 mm) O.D. spindles.

K435 - COIL ADAPTER

Permits 14 lb. (6 kg) Innershield coils to be mounted
on 2” (51 mm) O.D. spindles.

K363P - READI-REEL ADAPTER

Adapts Lincoln Readi-Reel coils of electrode 30 lb. (14
kg) and 22 lb. (10 kg) to a 2” (51 mm) spindle.
Durable molded plastic one piece construction.
Designed for easy loading; adapter remains on spin-
dle for quick changeover.

K438 - READI-REEL ADAPTER

Adapts Lincoln Readi-Reel coils of electrode 50-60 lb.
(22.7-27.2 kg) to a 2” (51 mm) spindle

POWER FEED 10 DUAL